Pedicure disc PODODISC from Staleks PRO is an innovative nail drill machine nozzle that is used to perform hardware pedicure. Special disposable abrasive files are attached to the surface of the pododisc.

THE USE OF PEDICURE DISCS HAS ADVANTAGES FOR BOTH THE TECHNICIAN AND THE CLIENT

  • Technician efforts reduction – compared with a foot file or nail drill bit, a disc is much easier and more comfortable to work with.
  • Reduction of the procedure duration – the disc allows you to increase the speed of the procedure at least two times.
  • Multifunctionality of the tool – a pedicure disc is a multipurpose tool that allows you to solve many different tasks: removing coarse skin, opening cracks, removing gel polish, and more.
  • Improving pedicure quality – due to a special movement trajectory, the disc qualitatively removes rough skin, not leaving the slightest flakes. This pedicure lasts much longer.
  • Economy – disc allows you not to use keratolytic and other means to prepare the foot before processing. The cost of disposable files is much lower than pedicure caps.
  • Safety – using disposable removable files minimizes the risk of infection.

PODODISC ARE AVAILABLE IN SEVERAL MODIFICATIONS AND DIFFERENT SIZES

PODODISC
Size: XS
PODODISC
Size: S
PODODISC
Size: M
PODODISC
Size: L

WATCH OUR FREE LESSONS TO IMPROVE YOUR PEDICURE WITH PODODISC FROM STALEKS PRO

Video Playlist
1/3 videos
1
The technique of working with pododisc - "Processing of problem feet cracks"
The technique of working with pododisc - "Processing of problem feet cracks"
2
The technique of working with pododisc - "Foot processing"
The technique of working with pododisc - "Foot processing"
3
Features of working with the Pododisc XS
Features of working with the Pododisc XS

PODODISC. Disinfection

There is a certain sequence of disinfection and sterilization of the instrument that must be followed.

Stages of processing manicure tools:

  • disinfection
  • pre-sterilization cleaning
  • sterilization

All instruments are considered infected after use and must be disinfected. The procedure is also necessary before starting work with new tools. After use, the instrument must be cleaned of coarse organic (anatomical) residues and wholly immersed in a disinfectant solution.

IMPORTANT! Exclude washing tools under running water to avoid the spread of infectious pathogens by splashes.

During disinfectants choosing, preference should be given to those that instructions for use indicate activity against hepatitis B, C, and dermatomycosis viruses. It is recommended to use disinfectants that contain a corrosion inhibitor. Corrosion inhibitor reduces the tool corrosion rate. It is better to use demineralized or distilled water to prepare a disinfectant solution and washing solutions.

IMPORTANT! During disinfection, carefully follow the instructions for the use of the product you have chosen! Failure to comply with the rules for the solution preparation and the exposure time can cause corrosion and loss of cutting properties of the tool.

After the disinfection procedure, it is necessary to rinse the instrument with water to remove the residues of the disinfectant solution and dry the tool thoroughly.

PODODISC. High temperature sterilization

STERILIZATION METHODS AND TEMPERATURE CONDITIONS :

Sterilization method

Devices

Sterilization

temperature, °C

Overpressure of

water steam, atm.

Sterilization time,

min

Steam

Autoclaves

132

2

20

120

1,1

45

Dry air (dry heat)

Dry heat sterilizers

180

 

60

160

 

150

IMPORTANT

  • During sterilization using high temperatures, residues of disinfectant or just water can lead to corrosion.
  • During sterilization in autoclaves and dry air sterilizer, the maximum permissible temperature must not be exceeded, or the sterilization time must not be lengthened (see table above). Such actions lead to a decrease in the corrosion resistance of the steel from which the manicure tool is made.
  • After sterilizing in autoclaves and the dry-heat sterilizer, leaving the steel instrument in an autoclave or dry-heat sterilizer is essential until it cools down (at least an hour). Otherwise, with a sharp temperature drop, the physical properties of steel are destroyed (the hardness of the metal decreases), and the tool will need to be sharpened much more often.